Part Number Hot Search : 
1051QA3 25002 U1000 100EP 10S24 BZG03C51 LTC17 B20200G
Product Description
Full Text Search
 

To Download EE-SPX743 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  photomicrosensor ee-spx74/84 compact sensor for high-density mounting with easy snap-in connector  connector features a built-in safety lock for shock and vibration resistance  sensor replacement made simple without rewiring  cables can be bent and used in a minimal amount of space  powerful light modulation against external light interference  variety of models available with an option to change from connector to pre-wired (ee-spx-w series) ordering information  ee-spx74/84 appearance sensing method slot width slot depth output configuration weight part number transmissive 3.6 mm 6.6 mm dark on approx. 2.4g ee-spx740 light on ee-spx840 dark on ee-spx742 light on ee-spx842 dark-on EE-SPX743 light-on ee-spx843 5.0 mm 9.0 mm dark-on ee-spx741 light-on ee-spx841
ee-spx74/84 ee-spx74/84 2 specifications  ratings/characteristics item ee-spx740, ee-spx840 ee-spx742, ee-spx842 EE-SPX743, ee-spx843 ee-spx741 ee-spx841 sensing distance 3.6 mm (slot width) 5 mm (slot width) standard sensing object opaque: 1 x 0.5 mm min opaque: 2 x 0.8 mm min differential travel 0.05 mm max. light source (peak emission wavelength) gaas infrared led (pulse modulated) (940 nm) indicator (see note 1) indicator (red) lit with incidence power supply voltage 5 to 24 vdc 10%, ripple (p-p): 5% max. current consumption average value: 15 ma max., peak value: 50 ma max. control output npn voltage output: load source voltage of 5 to 24 vdc and load current of 50 ma max. residual voltage: 1.0 v max. (at load current 50 ma) residual voltage: 0.4 v max. (at load current 10 ma) response frequency (see note 2) 500 hz ambient illuminance sensing surface: 3,000  x max. with incandescent light and sunlight ambient temperature operating: ?10 c to 55 c (14 f to 131 f) storage: ?25 c to 65 c (-13 f to 149 f) ambient humidity operating: 5% to 85% storage: 5% to 95% vibration resistance destruction: 10 to 55 hz, 1.5-mm double amplitude for 2 hours each in x, y, and z directions shock resistance destruction: 500 m/s 2 , three times each in x, y, and z directions enclosure rating iec60529 ip50 connection method (standard length) connector weight approx. 2.4 g casing material polycarbonate note: 1. the indicator is a gaalas red led (peak emission wavelength: 660 nm). 2. the value for response frequency was obtained using the ee-spx on a rotating disc with holes in it as shown below. 2 mm 2 mm 2 mm disk ee-spx741/841 disk ee-spx742/842 EE-SPX743/843 disk ee-spx740/840 engineering data  sensing position e-spx740/742/743 ee-spx741 distance d (mm) direction of insertion direction of insertion dark on distance d (mm) direction of insertion dark on distance d (mm) direction of insertion dark on distance d (mm) direction of insertion dark on
ee-spx74/84 ee-spx74/84 3 operation  output circuits output config- uration model output transistor operation timing charts output circuit npn output ee-spx740 ee-spx741 ee-spx742 EE-SPX743 dark on light on dark on on off light indicator (red) on off output transistor operate reset load 1 (e.g., relay) h l load 2 light indicator (red) main circuit load 1 (relay) 5 to 24 vdc out 1.5 to 3 ma + ee-spx840 ee-spx841 ee-spx842 ee-spx843 light on light on dark on on off light indicator (red) on off output transistor operate reset load 1 (e.g., relay) h l load 2 circuit note: voltage output (when connected to a transistor circuit or similar circuit) load 2 0 v ? (see note) dimensions unit: mm (inch)  ee-spx740 ee-spx840 optical axis (width: 0.5 mm) optical axis (width: 1 mm) operation indicator (red) two, 3.5 dia. terminal arrangement 1 ? gnd (0 v) 2 out output 3 + vcc 1 2 3 13.8 (0.54) 3.6 (0.14) 6.6 (0.26) 15.6 (0.61) 3 (0.12) 3 (0.12) 5.3 (0.21) 3.4 (0.13) 19 (0.75) 25 (0.98) 2.5 (0.10) 5 (0.20) 21.2 (0.83) 15.2 (0.60) 7 (0.28) 7.4 (0.29)  ee-spx742 ee-spx842 optical axis (width: 0.5 mm) optical axis (width: 1 mm) operation indicator (red) 3.5 dia. terminal arrangement 1 ? gnd (0 v) 2 out output 3 + vcc 1 2 3 2 dia. 2.5 (0.10) 13 (0.51) 3.6 (0.14) 2.5 (0.10) 6.6 (0.26) 8.3 (0.33) 5.3 (0.21) 3 (0.12) 5 (0.20) 2.5 (0.10) 21.2 (0.83) 6 (0.24) 6 (0.24) 7 (0.28) 2.6 (0.10) 15.6 (0.61) 6.5 (0.26)
ee-spx74/84 ee-spx74/84 4  EE-SPX743 ee-spx843 optical axis (width: 0.5 mm) optical axis (width: 1 mm) operation indicator (red) terminal arrangement 1 ? gnd (0 v) 2 out output 3 + vcc 1 2 3 2 dia. 3.5 dia. 2.5 (0.10) 13 (0.51) 3.6 (0.14) 2.5 (0.10) 6.6 (0.26) 8.3 (0.33) 5.3 (0.21) 3 (0.12) 2.5 (0.10) 5 (0.20) 7 (0.28) 6 (0.24) 2.6 (0.10) 15.6 (0.61) 21.2 (0.83) 6 (0.24) 6.5 (0.26)  ee-spx741 ee-spx841 operation indicator (red) optical axis (width: 0.8mm) optical axis (width: 2mm) two, 3.2 dia. terminal arrangement 1 ? gnd (0 v) 2 out output 3 + vcc 2 1 3 2.5 (0.10) 5 (0.20) 9 (0.35) 3.6 (0.14) 27.2 (1.07) 20 (0.79) 14.4 (0.57) 5 (0.20) 3.2 (0.13) 3 (0.12) 5.5 (0.22) 3 (0.12) 2.5 (0.10) 12.5 (0.49) 13.3 (0.52) 6.35 (0.25) 15.5 (0.61) 12.6 (0.50) 7.2 (0.28) 6.95 (0.27) 14.5 (0.57) 15.4 (0.61) 5.9 (0.23) 6.6 (0.26) 20 (0.79)  accessories (connector with cable) ee-1013 j.s.t. mfg. co., ltd. xhp-3 vinyl insulated round cable (3.5 dia., three conductors) (conductor cross-section: 0.14 mm 2 , insulator diameter: 1 mm) standard length: 1 m 3 2 1 terminal arrangement 1 blue gnd (0 v) 2 black output 3 brown vcc 2.5 (0.10) 9.8 (0.39) 5.7 (0.22) 7.75 (0.31) 20 (0.79) 1,000 (39.37) 16 2 (0.63 0.08 ) 7 1 (0.28 0.04 ) refer to the following when using a non-dedicated connector. manufacturer j.s.t. mfg. co., ltd. housing xhp-3 contact sxh-001t-p0.6 applied power line cross section 0.162 to 0.324 mm 2 awg# 25 to 22 insulator diameter 1.2 to 1.9 mm note: 1. for details, consult the manufacturer. 2. the applicable range for the applied power line is different from that specified by the manufacturer (awg# 28 to 22). 3. when using a cable longer than 4 m, refer to correct design setup in the precautions section .
ee-spx74/84 ee-spx74/84 5 precautions  installation connections do not connect the ee-spx to an ac (100 vac) power supply. doing so may cause ignition, burning, or other damage. sensor load brown black blue do not use the ee-spx at voltages exceeding the rated voltage range. doing so may cause the ee-spx to be damaged or burned. wire the ee-spx correctly with the correct polarity. failure to do so may cause the ee-spx to be damaged or burned. sensor load brown black blue do not short-circuit the load (i.e., do not connect a power supply directly to the sensor) as shown below. doing so may cause the ee-spx to be damaged or burned. sensor load brown black blue load short-circuiting  correct design setup cable extensions use a cable with a minimum wiring cross-section surface area of 0.15 mm 2 and no greater than 4 m in length. if the wiring exceeds 4 m, connect a 10 f capacitor within the 4 m mark, as shown in the diagram. (use a condenser with a withstand pressure of at least twice the sensor power source voltage.) 5 to 24 vdc capacitor 10 f min. 4 m max. extension cable 0 v power source when using a switching regulator on general sale, take the following countermeasures. 1. connect a 0 v line to the power source near the sensor to reduce impedance from the mounting, so as to prevent in- duction noise in the vicinity of the sensor. also, connect the line via a capacitor (up to 0.47 f). mounting base sensor switching power source (0.47 f) 0 v 2. connect a noise filter terminal (middle point terminal to acg) for the switching power source to the body of equipment (fg) for the power source and the 0 v. a more stable operation can be obtained by connecting the already-connected line to ground or to the mounting (as recommended by all power source manufacturers). sensor mounting base to power source to sensor switching power source input ground 0 v 3. insert a plastic insulator about 10 mm thick between the sen- sor and the mounting. effects of induced noise if there is induced noise in the (metal) mounting of the sensor, it may cause an effect similar to light on in the sensor. in such a case, connect the photomicrosensor 0 v terminal and the (metal) mounting at the same electric potential. also, connect the 0 v terminal and the metal mounting via a 0.47 f capacitor. sensor mounting base power source 5 to 24 vdc 0 v 0.47 f 0 v
ee-spx74/84 ee-spx74/84  mounting be sure to mount the sensor securely to flat plates. the characteristics of the through-beam sensor change if the slot is deformed. use m3.0 screws when mounting the ee-spx. be sure to use spring washers with the screws so that the screws will not loosen. the tightening torque applied to each screw must be no more than 0.59 n  m (6 kgf  cm). make sure that nothing will come into contact with the sensing element of the sensor. if the sensing element has scratch damage, the characteristics of the sensor will decrease. make sure that the ee-spx is securely mounted and not loosened by vibration or shock.  wiring countermeasures against surge if the power supply has surge voltage, connect a zener diode withstanding 30 to 35 v or 0.1 to 1- f capacitor in parallel to the power supply to absorb the surge voltage. z d : zener diode 0.1 to 1 f if the load is a relay or other small inductive load, connect the load to the ee-spx as shown below. be sure to connect a diode for counter-voltage absorption. relay +v 0 v do not wire power lines or high-tension lines alongside the lines of the ee-spx in the same conduit, otherwise the ee-spx may be damaged or malfunction due to induction. be sure to wire the lines of the ee-spx separately from power lines or high-tension lines or lay them in an exclusive, shielded conduit.  environment do not wire the ee-spx while power is applied, or the ee-spx may be damaged. to avoid damage or malfunction, do not install the ee-spx in the following locations: ? locations with excessive dust ? locations with corrosive gas ? locations where water, oil, or chemical is directly sprayed ? outdoors or locations exposed to direct sunlight make sure that the ambient operating temperature is within the rated range. the sensor may be soluble in organic solvent, acid, and alkaline, aromatic hydrocarbon, and chlorinated aliphatic hydrocarbon solvents. the characteristics of the sensor may decrease as a result, so make sure that the sensor is free from these solutions. cat. no. e309 ? e3 ? 1 7/00/2.5m specifications subject to change without notice. printed in u.s.a. omron electronics, inc. one east commerce drive schaumburg, il 60173 note: dimensions shown are in millimeters. to convert millimeters to inches divide by 25.4. 1-800-55-omron omron canada, inc. 885 milner avenue scarborough, ontario m1b 5v8 416-286-6465 


▲Up To Search▲   

 
Price & Availability of EE-SPX743

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X